Refrigerator thermostat circuit diagram analysis
The TC4011BP (Q801) is connected to two RS flip-flops. Among them, RS1 is used to control the operation of the compressor, and RS2 is used to control the defrosting work. The working process is as follows: when the RS11 pin is lowWhen 3 feet are high level, Q81I is turned on, RY01 is closed, and the compressor is turned on; when RS16 pin is low level, 3 feet is low level, QS11 is cut off, RY01 is released, and the compressor is stopped. When pressing the 'Defrost Start' button on the panel, the SET terminal, that is, the input pin 13 of RS2 is grounded, which is low level. At this time, the RS2 output terminal 11 is high level, Q812 is turned on, and RY02 is connected. The defrosting heating wire is energized to defrost. At the same time, because the Q812 collector is low, through the diodeD803, the Q811 is cut off, RY01 is released, and the compressor is forced to stop. ;When the refrigerator freezer temperature is higher than 8.5 °C, or when the 'Defrost Stop' (S...